If a load cell has a 5 volt dc vdc excitation voltage and a 0 250 mv output the resultant ratio is 250mv 5vdc.
Load cell calibration mv v.
If the load cell s sensitivity is 3 mv v and the excitation voltage provided by the converter is 10 volts then the divider will be 30 millivolts or 0 03 volts.
This equates to 50 mv per volt or has a 50 1 ratio.
This load cell sensitivity rating is specified on a load cell data sheet often in the 1 mv v 3 mv v range.
The difference voltage proportional to the load then appears on the signal outputs.
Most quality load cells will come with a factory load cell calibration sheet which specifies the actual sensitivity rating for that individual load cell.
Figure 3 above is an example of a morehouse calibration shear web load cell with a non linearity specification of better than 0 05 of full scale.
Span sensitivity mv v this is the full span output per supply volt characteristic for the load cell wheatstone bridge.
This load cell sensitivity value can be used to convert the load cell s output.
Supply voltage v this is the excitation voltage in volts applied to the load cell wheatstone bridge strain gauge circuit.
When shopping for load cells you are typically provided with two pieces of information about the load cell excitation voltage v orvdc and output mv.
The millivolt output of a non amplified load cell is linearly proportional to the excitation voltage.
Divide the product from step 2 2 7 volt pounds by sensitivity in millivolts volt times the excitation voltage.